4.1.2.2 A/B Selector Push Button Settings
There are four (4) different types of A/B selector sequences available on the Flex system.
Choose the one that is most suitable for your application.
Type-A selector sequence : A+B → A → B → A+B …
Type-B selector sequence : Off → A → B → Off → A → B …
Type-C selector sequence : A → B → A+B → A → B → A+B …
Type-D selector sequence : Off → A → B → A+B → Off → A → B → A+B …
DIP PB1 PB2 PB3 PB4
6
00011101 Normal Normal A/1&2 Normal
7
00011110 Normal Normal B/1&2 Normal
8
00011111 Normal Normal C/1&2 Normal
9
00100000 Normal Normal D/1&2 Normal
10
00100001 Normal Normal Normal A/3&4
11
00100010 Normal Normal Normal B/3&4
12
00100011 Normal Normal Normal C/3&4
13
00100100 Normal Normal Normal D/3&4
14
00100101 Normal Normal A/1&2 A/3&4
15
00100110 Normal Normal A/1&2 B/3&4
16
00100111 Normal Normal A/1&2 C/3&4
17
00101000 Normal Normal A/1&2 D/3&4
18
00101001 Normal Normal B/1&2 B/3&4
19
00101010 Normal Normal B/1&2 C/3&4
20
00101011 Normal Normal B/1&2 D/3&4
21
00101100 Normal Normal C/1&2 C/3&4
22
00101101 Normal Normal C/1&2 D/3&4
23
00101110 Normal Normal D/1&2 D/3&4
* PB1…PB4 → Push button number
* Normal → Normal momentary contact
* A/1&2…D/3&4 → A/B Selector type with designated LED Display (LED 1&2 or LED 3&4)