COM 1 2 3 4
6. I-CHIP Programming Port
(Fig. 17)
I-CHIP programming port located on the decoder module (refer to Fig. 17 above) inside the receiver is
designed for the purpose of transferring system serial number/ID code either from I-CHIP to receiver or
from receiver to I-CHIP. If you wish to transfer system information from receiver to I-CHIP, just insert
the I-CHIP onto the programming port (JP6 jumper not inserted), wait until the Status LED on the
decoder module turned constant green (within 2 seconds), and then take the I-CHIP out of the
programming port (programming completed). At this time the I-CHIP should also possess the same
serial number/ID code as the receiver. If the Status LED on the decoder module displayed a constant red
light after inserting the I-CHIP (programming failed), then you must reinsert the I-CHIP one more time.
On the other hand, if you wish to transfer system information from I-CHIP to receiver, then you must
first insert JP6 jumper prior to inserting the I-CHIP, then wait for the green light to appear on the Status
LED. At this time the receiver should also possess the same system information as the I-CHIP. Please
note that the receiver unit must be powered in order to proceed with the programming.
7. Voltage Settings
Prior to installation always check the voltage setting is correct for your application (refer to Fig. 18
below).
Position 1 110~120VAC
Position 2 220~240VAC or 24VAC*
Position 3 380~410VAC or 42VAC*
Position 4 440~460VAC or 48VAC* or 12~24VDC**
* For system with 24/42/48VAC power supply. (Fig. 18)
** For system with 12~24VDC power supply.
F9 and F10 power fuse ratings:
FUSE # 110~120VAC 220~240VAC 380~410VAC 440~460VAC 24VAC 42 & 48VAC 12~24VDC
F9
1.0A (red) 1.0A (red) 1.0A (red) 0.5A (blue) 3.0A (yellow) 2.0A (purple) 2.0A (purple)
F10
1.0A (red) 1.0A (red) 1.0A (red) 0.5A (blue) 3.0A (yellow) 2.0A (purple) 2.0A (purple)